Trace Spacing Guidelines

Voltage Between Conductors (VDC or Peak)

Minimum Spacing (inches)

Bare Board

Assembly

B1

B2

B3

B4

A5

A6

A7

0 thru 15

.004

.025

.025

.005

.005

.005

.005

16 thru 30

.004

.025

.025

.005

.005

.010

.005

31 thru 50

.004

.025

.025

.005

.005

.015

.005

51 thru 100

.004

.025

.060

.005

.005

.020

.005

101 thru 150

.008

.025

.125

.015

.015

.030

.015

151 thru 170

.008

.050

.125

.015

.015

.030

.015

171 thru 250

.008

.050

.250

.015

.015

.030

.015

251 thru 300

.008

.050

.500

.015

.015

.030

.015

301 thru 500

.010

.100

.500

.030

.030

.060

.030

More than 500

.0001
 /Volt

.0002 /Volt

.001 /Volt

.00012 /Volt

.00012 /Volt

.00012 /Volt

.00012 /Volt

B1 - Internal Conductors
B2 - External Conductors, uncoated, sea level to 10,000 ft.
B3 - External Conductors, uncoated, over 10,000 ft.
B4 - External Conductors, with permanent polymer coating (soldermask).
A5 - External Conductors, with conformal coating over assembly.
A6 - External Component lead/termination, uncoated.
A7 - External Component lead/termination, with conformal coating.